Modbus Display · MD Series

Modbus Display

Modbus Displays are industrial-grade digital displays designed specifically for Modbus automation environments — reading data directly from Modbus RS485 or Modbus TCP/IP networks without intermediate gateways or converters. They work…

Modbus RS485 Modbus TCP/IP Master & Slave Modes 4–12 Inch Displays Flexible Digit Configuration
Modbus Display
Direct Modbus Integration Read data directly from Modbus RS485 or TCP/IP networks — no gateway or conversion required
Flexible Sizing Available in 4", 6", 8", and 12" heights with 4 to 10 configurable digits
Dual-Mode Operation Function as Modbus slave (read from network) or master (write to network) depending on application
Custom Configuration Set display address, register mapping, and update frequency during commissioning — no reprogramming needed

Modbus-Native Data Display for Industrial Control Systems.

Modbus Displays are industrial-grade digital displays designed specifically for Modbus automation environments — reading data directly from Modbus RS485 or Modbus TCP/IP networks without intermediate gateways or converters. They work as transparent display nodes on your network, pulling the exact register values you specify and showing them in large, bright digits.

Available in multiple sizes (4", 6", 8", and 12" digit heights) with configurable digit counts (4 to 10 digits per display), these boards suit any Modbus application — pumping stations, gating systems, SCADA networks, or standalone Modbus-enabled instruments at remote locations. Configure each display to read from a specific device ID and register address during setup.

These displays operate as Modbus slaves by default (receiving data from a network master like a PLC or SCADA system) but can be configured as Modbus masters to query and control remote devices when required.

  • Available in 4", 6", 8", and 12" digit heights for enhanced visibility.Configurable digit counts from 4 to 10 to suit specific data display needs.Supports Modbus TCP/IP for Ethernet-based communication over LAN or WAN.Supports Modbus RS485 for serial communication over long distances.Operates as a Modbus master to query and control slave devices.Functions as a Modbus slave to display data from a master device.Bright LED digits for high visibility in indoor and outdoor environments.Field-configurable device ID, register address, and data format without software downloads.Durable, industrial-grade housing resistant to dust, moisture, and temperature variations.
Modbus Display
10
Max Digit Count
12
Largest Size Available
2
Communication Protocols
100+
Worldwide Installations

Full Specification Table

Modbus Displays Specifications
Display Sizes4", 6", 8", 12"
Digit Counts4, 5, 6, 7, 8, 9, 10 digits — field-configurable
Input ProtocolsModbus TCP/IP, Modbus RS485 (RTU and ASCII)
Master/Slave CapabilityDefault slave (receives data). Can be configured as master to query network devices.
Register AddressingConfigurable device ID (1–247) and register address (0–65535)
Data Types16-bit and 32-bit integers, signed and unsigned, with scaling
Update FrequencyConfigurable from 0.1s to 60s per read cycle
Display RangeFull range of data type (e.g., 0–65535 for unsigned 16-bit)
Decimal PlaceField-settable via interface (0–5 decimal places)
LED ColorBright red 7-segment
VisibilityIndoor and outdoor with high-brightness LED
Power Supply100–240V AC, 50/60Hz (standard) or 24V DC (optional)
Operating Temperature–10°C to +60°C
Storage Temperature–20°C to +80°C
HousingIndustrial-grade plastic or metal enclosure, dust and moisture resistant (IP54 standard)
MountingWall-mounted or DIN rail mount (size dependent)
Communication AdapterRS485 terminal or Ethernet RJ45 (protocol dependent)
Configuration MethodLocal via buttons/interface or remote via Modbus commands

Ordering Information

SegmentCode optionsDescriptionSize04, 06, 08, 12Digit height in inchesDigits4D, 5D, 6D, 7D, 8D, 9D, 10DNumber of digits in displayInput485 (RS485), TCP (TCP/IP)Modbus communication typeOutputOP0 (none), OP1 (relay alarm)Optional alarm relay outputIP RatingIP54, IP65Enclosure protection levelPowerPS1 (230V AC), PS2 (24V DC)Electrical supply

Where It's Deployed

Typical applications

  • PLC / SCADA monitoring — display critical register values from PLCs or industrial PCs on the shop floor
  • Pump station control — show flow rate, pressure, or tank level from Modbus sensors to operators
  • Gating and water management — display gate position, water level, or flow on a remote display board
  • Remote monitoring — install displays at multiple points in a distributed control network
  • Equipment status boards — show equipment health, phase voltage, or load percentage on a single display
  • Integration with existing Modbus networks — add a display to any Modbus RS485 or TCP/IP network

Data types supported

  • Modbus registers — 16-bit signed and unsigned integers
  • 32-bit values — combine two consecutive registers for larger numbers
  • Scaling — multiply by factor and add offset during display (e.g., raw value 450 displayed as 45.0)
  • Engineering units — technician-selectable units during configuration