Electromed — Header + Mega Menu v2
Browse
All Products 5 categories
Categories
LED Display Boards 8 products
Multi Channel Display Boards 7 products
Jumbo Displays and Digital Indicators 9 products
Jumbo Clocks 10 products
Queue Management Systems 5 products
Modbus Display · MD Series

Modbus Display

Modbus Displays are industrial-grade LED displays designed specifically for Modbus automation environments — reading register values directly from Modbus RS485 or Modbus TCP/IP networks without intermediate gateways or converters. Connect…

Modbus RS485 Modbus TCP/IP Master & Slave Modes 4–12 Inch Displays 4–10 Digit Configuration
Modbus Display
Direct Modbus Integration Reads register values directly from RS485 or TCP/IP networks — no gateway or signal converter needed
4" to 12" Digit Height Choose the display size that matches your visibility requirement — from instrument panel to plant floor
Master & Slave Modes Operates as Modbus slave by default — configurable as master to query and control remote devices
Field Configurable Set device ID, register address, decimal places, and scaling at commissioning — no software download required

Modbus-Native Display for Industrial Control Systems.

Modbus Displays are industrial-grade LED displays designed specifically for Modbus automation environments — reading register values directly from Modbus RS485 or Modbus TCP/IP networks without intermediate gateways or converters. Connect it to your existing PLC or SCADA network, set the device ID and register address, and live data appears instantly in large bright digits.

Available in 4", 6", 8", and 12" digit heights with 4 to 10 configurable digits per display — suited for any parameter on any Modbus network, from pump station flow rates to SCADA register values. Each display operates as a Modbus slave by default but can be configured as a master to query remote devices when required.

  • 4", 6", 8", and 12" digit heights — choose per installation requirement
  • Configurable digit count from 4 to 10 per display
  • Modbus RS485 (RTU and ASCII) and Modbus TCP/IP over Ethernet
  • Operates as Modbus slave (default) or master — application dependent
  • Field-configurable device ID (1–247) and register address (0–65535)
  • 16-bit and 32-bit integers, signed and unsigned, with scaling and offset
  • Decimal point field-settable from 0 to 5 places
  • Update frequency configurable from 0.1s to 60s per read cycle
  • Bright red 7-segment LED — high visibility indoors and outdoors
  • IP54 standard enclosure — IP65 available for wet or dusty locations
  • 100–240V AC standard, 24V DC optional
Modbus Display
10
Max Digit Count
12"
Largest Digit Height
2
Modbus Protocols
100+
Installations

Full Specification Table

ParameterSpecification
Display Sizes4", 6", 8", 12"
Digit Count4 to 10 digits — field-configurable
Input ProtocolsModbus RS485 (RTU and ASCII), Modbus TCP/IP over Ethernet
Master / SlaveDefault slave — configurable as master to query network devices
Register AddressingDevice ID 1–247, register address 0–65535
Data Types16-bit and 32-bit integers, signed and unsigned, with scaling and offset
Update Frequency0.1s to 60s per read cycle — field-configurable
Decimal Place0 to 5 decimal places — field-settable
Display RangeFull data type range (e.g. 0–65535 for unsigned 16-bit)
LED ColourBright red 7-segment
Power Supply100–240V AC, 50/60 Hz (standard) · 24V DC (optional)
EnclosureMS powder-coated, IP54 standard, IP65 on request
Operating Temperature–10°C to +60°C
MountingWall-mounted or DIN rail (size dependent)
ConfigurationLocal via front panel buttons or remote via Modbus commands

Ordering Information

ParameterOptions
Code FormatMD[SIZE]-[CABINET]-[DIGITS]-[INPUT]-[OUTPUT]-[IPRATING]-[PS]
Display Size04 — 4" · 06 — 6" · 08 — 8" · 12 — 12"
CabinetSS — Single Side · DS — Double Side
Digit Count4D — 4 Digit · 5D — 5 Digit · 6D — 6 Digit · 7D — 7 Digit · 8D — 8 Digit · 9D — 9 Digit · 10D — 10 Digit
InputIN2 — Modbus RS485 (default) · IN3 — Modbus TCP/IP
OutputOP0 — None · OP1 — Relay
IP RatingIP54 — Standard · IP65 — Wet/Dusty locations
Power SupplyPS1 — 230V AC · PS2 — 24V DC
Example order code
MD04 SS 4D IN2 OP0 IP54 PS1
MD04-SS-4D-IN2-OP0-IP54-PS1

Modbus Display, 4 Inch, Single Side, 4 Digit, Modbus RS485, No Output, IP54, 230V AC

Where It's Deployed

Typical applications

  • PLC / SCADA monitoring — display critical register values from PLCs or industrial PCs on the shop floor
  • Pump station control — show flow rate, pressure, or tank level from Modbus sensors to operators
  • Gating and water management — display gate position, water level, or flow on a remote display board
  • Remote monitoring — install displays at multiple points in a distributed control network
  • Equipment status boards — show equipment health, phase voltage, or load percentage on a single display
  • Integration with existing Modbus networks — add a display to any Modbus RS485 or TCP/IP network

Data types supported

  • Modbus registers — 16-bit signed and unsigned integers
  • 32-bit values — combine two consecutive registers for larger numbers
  • Scaling — multiply by factor and add offset during display (e.g., raw value 450 displayed as 45.0)
  • Engineering units — technician-selectable units during configuration

Our Valued Customers

Need a Quote or Custom Spec?

Our engineers respond within 24 hours. Tell us your display size, range and quantity.

Scroll to Top